The terms you are most likely to meet in a quote or on a product label in Australia, in plain English.
A
- ACOP (Annual Coefficient of Performance)
- A measure of heating efficiency: the heat delivered divided by the electricity used, averaged across a year. Higher is better.
- AEER (Annual Energy Efficiency Ratio)
- The cooling equivalent of ACOP. Cooling delivered divided by electricity used, averaged across a year. Higher is better.
- ARC (Australian Refrigeration Council)
- The body that administers refrigerant licensing in Australia on behalf of the Australian Government. You can check whether a technician or business is licensed on its public register at lookforthetick.com.au.
B
- BTU (British thermal unit)
- A unit of heat energy. Used on American products and occasionally on imported units. Australia uses kilowatts. For reference, 1kW is about 3,412 BTU per hour.
- Bulkhead unit
- An indoor unit concealed in a bulkhead or ceiling void, feeding one or two outlets. Between a split and a ducted system in concept.
C
- Capacity
- How much heating or cooling a system can deliver, measured in kilowatts (kW) in Australia. Heating and cooling capacity are different numbers for the same unit. The most important figure in your quote.
- Cassette
- An indoor unit set flush into the ceiling with only a grille visible, blowing air in two, three or four directions. Not the same as ducted.
- Compressor
- The pump in the outdoor unit that circulates refrigerant around the system. Often described as the heart of the system.
- Condenser
- The coil where refrigerant releases heat and turns back into a liquid. In cooling mode this is the outdoor coil.
- COP (Coefficient of Performance)
- Heating output divided by electrical input, at a single test condition. A COP of 4 means four units of heat for one unit of electricity.
D
- Damper
- A motorised flap in ductwork that opens or closes a zone. How zoning works on a ducted system.
- dB(A)
- Decibels on the A-weighted scale, the standard measure of how loud something is. Shown on the energy label for indoor and outdoor units.
- DRED (Demand Response Enabling Device)
- A feature that lets an electricity network temporarily reduce an air conditioner’s output during periods of extreme demand. Some networks offer incentives for enabling it.
- Dry mode
- A setting that runs the system to remove humidity rather than lower temperature. Uses less energy than full cooling, but it is not a dehumidifier and its effect is limited.
- Ducted system
- A system with an indoor unit in the roof space or under the floor, distributing conditioned air through ducts to vents throughout the home. See our guide to ducted systems.
E
- EER (Energy Efficiency Ratio)
- Cooling output divided by electrical input, at a single test condition. In Australia both are expressed in watts, so an EER of 3.5 means 3.5 units of cooling for one unit of electricity. Note that in the United States EER is calculated differently, using BTU per hour per watt, so American figures are not comparable.
- Evaporative cooling
- Cooling air by passing it over water-saturated pads. Effective in dry heat, much less so in humidity. Uses far less electricity than refrigerated air conditioning, but uses water and cannot heat. See how evaporative cooling works.
- Evaporator
- The coil where refrigerant absorbs heat and boils into a gas. In cooling mode this is the indoor coil.
G
- GEMS (Greenhouse and Energy Minimum Standards)
- The national scheme that sets minimum efficiency standards and labelling requirements for appliances sold in Australia, including air conditioners.
- GWP (Global Warming Potential)
- A measure of how much a gas contributes to warming compared with carbon dioxide. Relevant to refrigerants: R32 has roughly one third the GWP of the R410A it has largely replaced.
H
- Heat load assessment
- The calculation that determines what capacity your home actually needs. It accounts for room sizes, ceiling height, insulation, building materials, and window size and orientation. A quote based on floor area alone is a guess. See what size air conditioner you need.
- Heat pump
- In air conditioning, another name for a reverse cycle system: one that heats as well as cools by moving heat rather than generating it. Note that a heat pump hot water system is a different appliance that heats water, not air. See heat pump systems.
- High wall
- A wall-mounted indoor unit installed high on the wall. The most common type of split system indoor unit.
- HSPF (Heating Seasonal Performance Factor)
- A seasonal measure of heating efficiency used in Australian energy labelling. It reflects performance across a range of outdoor temperatures rather than at one test point, which makes it a more realistic guide than a single COP figure.
- HVAC
- Heating, ventilation and air conditioning.
I
- Inverter
- Technology that varies the compressor speed instead of switching it on and off. Lower running costs, steadier temperatures, quieter operation and better dehumidification. Standard on nearly all split and ducted systems sold today. See inverter air conditioners.
K
- kW (kilowatt)
- The unit used for air conditioner capacity in Australia. One kilowatt is 1,000 watts, or about 3,412 BTU per hour. Do not confuse the capacity in kW with the power input in kW, which is much smaller.
- kWh (kilowatt hour)
- A unit of energy, and what you are billed for. The energy label shows estimated annual energy use in kWh.
M
- MEPS (Minimum Energy Performance Standards)
- The minimum efficiency a product must meet to be legally sold in Australia. A floor, not a target.
- Multi-split
- Several indoor units connected to one outdoor unit, each separately controlled. Most cannot heat one room while cooling another. See multi-split systems.
P
- Packaged unit
- A system with all components in a single outdoor cabinet, connected to the building by ductwork. Mostly a commercial product in Australia. See packaged air conditioners.
R
- R22
- An older refrigerant that does deplete the ozone layer. Phased out. If your existing system uses it, servicing is expensive and getting harder, and replacement is usually the better option.
- R32
- The refrigerant used in most new split systems sold in Australia. It does not deplete the ozone layer, and it has roughly a third the global warming potential of R410A. Classified as mildly flammable (safety class A2L), which is one reason licensed installation matters.
- R410A
- The refrigerant widely used before R32. It does not deplete the ozone layer either, but its global warming potential is much higher, so it is being phased down.
- Refrigerant
- The fluid that carries heat around the system, changing between liquid and gas. Must be handled by a licensed technician.
- Refrigerant Handling Licence (RHL)
- The licence an individual must hold to install, service or decommission air conditioning equipment. RAC01 covers all work. RSS03 is restricted to installing and decommissioning single-head split systems under 18kW and does not permit servicing. See how to check an installer.
- Refrigerant Trading Authorisation (RTA)
- The authorisation a business must hold to acquire, store, sell or dispose of refrigerant.
- Reverse cycle
- A system that can run its refrigeration circuit in either direction, so it heats as well as cools. Same thing as a heat pump. See reverse cycle systems.
S
- SEER (Seasonal Energy Efficiency Ratio)
- A United States efficiency metric. It is not used on Australian energy labels. Australia uses star ratings on the Zoned Energy Rating Label, derived from TCSPF and HSPF. Ignore SEER figures when comparing systems sold here.
- Split system
- A system in two parts: an outdoor unit containing the compressor and condenser, and an indoor unit containing the evaporator and fan, joined by refrigerant pipes. The most common type in Australian homes. See split systems.
T
- TCSPF (Total Cooling Seasonal Performance Factor)
- A seasonal measure of cooling efficiency used in Australian energy labelling, reflecting performance across a range of outdoor temperatures. One of the two figures behind the star rating.
- Three phase
- A heavier electrical supply used by larger systems. Most homes have single phase. Three-phase systems are not required to carry an energy rating label.
Z
- Zoned Energy Rating Label (ZERL)
- The label on air conditioners sold in Australia since 1 Apr 2020. It shows star ratings from 1 to 10 for heating and cooling in each of three climate zones (hot, average and cold), estimated annual energy use in kWh, capacity in kW, and noise levels. Mandatory in store for single-phase, non-ducted, unitary or single-split systems up to 30kW. See choosing a reliable system.
- Zoning
- Dividing a ducted system into areas that can be turned on and off independently, so you condition only the rooms you are using. Note that on most systems all open zones share one thermostat, so zoning is not the same as individual room temperature control.
Useful independent resources
- energyrating.gov.au and the Energy Rating Calculator: compare star ratings and estimated running costs for your climate zone
- energy.gov.au/rebates: the Australian Government’s rebate and assistance finder
- lookforthetick.com.au: check an installer’s refrigerant licence
- Australian Refrigeration Council: refrigerant licensing and industry information
- fairair.com.au: consumer information and a sizing calculator from AIRAH, the Australian Institute of Refrigeration, Air Conditioning and Heating
- choice.com.au: independent lab testing and reviews